This temperature controller operates as a pulse snatching device, which  allows it to run at its own  speed and tum on at the zero crossing of  the line frequency. Zero crossing tum-on reduces the generation  of line  noise transients. TMOS Power FET, Ql, is used to tum on a heater.   Temperature sensor D6 provides a de voltage proportional to temperature  that is applied to voltage-tofrequency  converter Ul. Output from Ul is a  pulse train proportional to temperature offset that is applied  to the  input of triac optoisolator U2.
Proportional-Temperature-Controller Circuit Diagram
Proportional-Temperature-Controller Circuit Diagram
The anode supply for the triac is a 28 V pk-pk, full-wave rectified sine   wave. The optoisolator ORs the pulse train from Ul with the  zeroTrossing of U2`s anode supply, supplying  a gate tum on signal for  Ql. Therefore, TMOS power FET Ql can only tum the heater on at the zero   crossing of the applied sine wave. The maximum temperature, limited by  the sensor and the insulation of  the wire, is 130°C for the components  shown.    
 

 
 
 
 
 
 
 
 
 
 