Ups System mini Circuit Diagram

This is the Ups System mini Circuit Diagram. This Ups System mini circuit provides an uninterrupted  power supply (UPS) to operate 12V, 9V and 5V DC-powered instruments at up to 1A current. The backup battery takes up the load without spikes or delay when the mains power gets interrupted. It can also be used as a workbench power supply that provides 12V, 9V and 5V operating voltages. The circuit immediately disconnects the load when the battery voltage reduces to 10.5V to  prevent deep discharge of the battery.  LED1  indication  is  provided  to  show  the full charge voltage level of the battery. miniature white LEDs (LED2 and  LED3) are used as emergency lamps during power failure at night. 


Mini Ups System Circuit Diagram
Mini Ups System Circuit Diagram

A standard step-down transformer provides 12V of AC, which is rectified by diodes D1 and D2. Capacitor C1 provides ripple-free DC to  charge the battery and to the remaining circuit. When the mains power is  on, diode D3 gets forward biased to charge the battery. Resistor R1 limits the charging current. Potentiometer VR1 (10k) with transistor T1 acts as the voltage comparator to indicate the voltage level. VR1 is so adjusted that LED1 is in the ‘off’ mode. When the battery is fully charged, LED1 glows indicating a full voltage level of 12V. 

When the mains power fails, diode D3 gets reverse biased and D4 gets forward biased so that the battery can automatically take up the load without any delay. When the battery voltage or  input voltage  alls below 10.5V, a cut-off circuit is used  to prevent deep discharging of the battery. Resistor R3, zener diode  ZD1 (10.5V) and transistor  T2  form  the  cut-off circuit. When the voltage level is above 10.5V, transistor T2 conducts and its base becomes negative (as set by R3, VR2 and ZD1). But when the voltage reduces below  10.5V, the zener diode stops conduction and the base voltage of transistor T2 becomes positive. It goes into the ‘cut-off’ mode and prevents the current in the output stage. Preset VR2 (22k) adjusts the voltage below 0.6V to make T2 work if the voltage is above 10.5V. 

When power from the mains is available, all output voltages—12V, 9V and 5V—are ready to run the load. On the other hand, when the mains  power is down, output  volt-ages can run the load only when the  battery is fully charged (as indicated by LED1). For the partially charged battery, only 9V and 5V are available. Also, no output is available when the voltage goes below 10.5V. If battery voltage varies between 10.5V and  13V, output at terminal A may also vary between 10.5V and 12V, when the UPS system is in battery mode.
Outputs at points B and C provide 9V and 5V, respectively, through regulator ICs (IC1 and IC2), while output A provides 12V through the zener diode. The emergency lamp uses two ultra-bright white LEDs (LED2 and LED3) with current limiting resistors R5 and R6. The lamp can be manually switched ‘on’ and ‘off’ by S1. The circuit is assembled on a general purpose PCB. There is adequate space between the components to avoid overlapping. heat sinks for transistor T2 and regulator ICs (7809 and 7805) to dissipate heat are used. 

The positive and negative rails should be strong enough to handle high current. Before connecting the circuit to the battery and transformer, connect it to a variable power supply. Provide 12V DC and adjust VR1 till LED1  glows. After setting the high voltage  level, reduce the voltage to 10.5V and adjust  VR2  till  the  output  trips  off.  After  the  settings  are complete, remove the variable power sup-ply and connect a fully-charged battery to the terminals and see that LED1 is  on. After making all the adjustment connect the circuit to the battery and transformer. The battery used in the circuit is a 12V, 4.5Ah UPS battery. 

0 comments:

Post a Comment